Nokta-detectors Golden Sense Quick Guide Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Sports et loisirs Nokta-detectors Golden Sense Quick Guide. Nokta detectors Golden Sense Quick Guide User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
QUICK GUIDE
GROUND BALANCE
Rotate the
sensitivity knob
to maximum
and the ground
balance knob to
the mid-level.
If the detector emits false signals due to interference,
reduce the sensitivity until the signals go away and
start searching.
Sensitivity is also the depth setting for the device.
Therefore, it is recommended that you do not lower it
too much suddenly but gradually decrease it to
determine the level where you are not getting any
interference and continue searching.
Holding the search coil 5cm.
above the ground, sweep it
right and left.
Turn on the device
by setting the
search mode knob
to ALL METAL.
Approximately 20
seconds later, the LEDs
on the handle will go o
and you will hear a tone
indicating that the device
is ready to use.
When the device detects a metal, it will produce an audible tone. For pinpointing the exact location of the target, move the search coil
over the target with short and faster/slower sweeps.
The most important thing to pay attention here is that as the ground balance goes into the right area, the device will start losing depth
for some non-ferrous metals except for gold. When the ground balance setting reaches the maximum point the device will detect iron
and gold but it will not detect some non-ferrous metals.
3) RIGHT AREA: Is used to eliminate high mineralized rocks and soils. If you are on a highly mineralized ground and the device is still getting
ground noise with the ground balance set at mid-level, turn the ground balance knob to the right in very small increments to eliminate the
noise.
Golden Sense ground balance setting consists of 3 dierent levels:
1) MID-LEVEL: Oers the most ideal and stable detection capability on dierent types of
grounds without sacrificing depth.
2) LEFT AREA: Recommended for more precise detections and for experienced users.
The device may generate false signals in changing ground conditions, even over holes
dug for testing. Therefore, if you set the ground balance in this area, you have to take
this factor into consideration.
After the ground balance and
sensitivity settings are
adjusted, you can start
searching by lifting the search
coil 5cm. above the ground and
sweeping it right and left,
keeping it parallel to the
ground.
To avoid missing smaller and
deeper targets, sweep the
search coil both from right to
left and left to right over each
area you are scanning, slightly
overlapping the sweeps as you
move forward.
GROUND BALANCE
2) LEFT AREA
3) RIGHT AREA
1) RECOMMENDED SETTING
MID-LEVEL
SENSITIVITY
SENSITIVITY
TURNING ON THE DEVICE
SENSITIVITY SETTING
1
2
SEARCHING AND METAL DETECTION
3
Vue de la page 0
1 2

Résumé du contenu

Page 1 - QUICK GUIDE

QUICK GUIDEGROUND BALANCERotate the sensitivity knob to maximum and the ground balance knob to the mid-level.If the detector emits false signals due t

Page 2

Insert the coil cable into the shaft. Do not extend the shaft prior to this step! Pull the cable out from the other end of the shaft.Coil cover use is

Commentaires sur ces manuels

Pas de commentaire